HAS 500-S

Electrical data

IP N Primary nominal RMS current 500 A
IP M Primary current, measuring range 0 … ±900 A
UC Supply voltage (±5 %) 1) ±15 V
IC Current consumption ±15 mA
RINS Insulation resistance @ 500 V DC > 1000 MΩ
Uout Output voltage (Analog) @ ±IP N, RL = 10 kΩ, TA
= 25 °C ±4 V V
Rout Output internal resistance approx 100 Ω
RL Load resistance 2) > 1 kΩ

Accuracy – Dynamic performance data
ε Error @ IP N, TA = 25 °C (excluding offset) < ±1 %
εL Linearity error 3) (0 … ±I
P N) < ±1 % of IP N
UO E Electrical offset voltage, TA = 25 °C < ±20 mV
UO H Hysteresis offset voltage @ IP N = 0,
after an excursion of 1 × IP N < ±20 mV
TCUO E Temperature coefficient of UO E −40 °C… +85 °C < ±1 mV/K
+85 °C… +105 °C < ±1.5 mV/K
TCUout Temperature coefficient of Uout (% of reading) < ±0.1 %/K
t
D 90 Delay time to 90 % of IP N
4) < 3 µs
BW Frequency bandwidth (−3 dB) 5) DC … 50 kHz

General data
TA     Ambient operating temperature                   −40 … +105 °C
TS     Ambient storage temperature                        −40 … +105 °C
m       Mass                                               approx        60 g
Standard                                 UL                                UL 508:2010 6)
EMC                                                                              IEC 61000-6-2:2016
IEC 61800-3:2017 7)
Safety                                                                            IEC 61010-1:2010
Environmental                                                           IEC 61477-1:2012
IEC 61800-2:2012